EVO Systems 9
5.8 Auto-Arming
If enabled by your installer, you can set the time that an area will arm itself automatically.
5.8.1 Timed Auto-Arming
Your installer can set Timed Auto-Arming to function in either Force or Stay arming
mode. A sixty-second (default value) Exit Delay sequence will begin prior to your
system automatically arming itself at the programmed time.
To set the Auto-Arming timer:
1. Enter your [
ACCESS CODE].
2. Press the [0] button.
3. Press the [
MEM] button.
4. If you have access to more than one area, press the area’s
number, or use the
[S] and [T] buttons and press the [
ACC] button when the area you want to
program appears on the screen.
5. Enter the time you want the area to be armed according to the 24-hour clock
(i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).
6. Press the [
ENTER] button to save and exit.
If you are using the DGP2-648BL LED keypad, The
MEM action light will
flash if a time is not already programmed. The
PRG action light, the area
light of the chosen area, and the first number of the previous time set will
illuminate (
10 light = zero).
5.8.2 No Movement Auto-Arming
Your system can be programmed to send a report to your monitoring station and/
or arm the system if there is no activity in the area during a specified period of
time. Your installer can set No Movement Auto-Arming to function in either
Regular or Stay arming mode.
LCD LED