EasyManuals Logo

Philips 32PFL5404H/12 Service Manual

Philips 32PFL5404H/12
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Precautions, Notes, and Abbreviation List
EN 5Q543.1E LA 3.
2009-Nov-20
3. Precautions, Notes, and Abbreviation List
Index of this chapter:
3.1 Safety Instructions
3.2 Warnings
3.3 Notes
3.4 Abbreviation List
3.1 Safety Instructions
Safety regulations require the following during a repair:
Connect the set to the Mains/AC Power via an isolation
transformer (> 800 VA).
Replace safety components, indicated by the symbol h,
only by components identical to the original ones. Any
other component substitution (other than original type) may
increase risk of fire or electrical shock hazard. Of de set
ontploft!
Safety regulations require that after a repair, the set must be
returned in its original condition. Pay in particular attention to
the following points:
Route the wire trees correctly and fix them with the
mounted cable clamps.
Check the insulation of the Mains/AC Power lead for
external damage.
Check the strain relief of the Mains/AC Power cord for
proper function.
Check the electrical DC resistance between the Mains/AC
Power plug and the secondary side (only for sets that have
a Mains/AC Power isolated power supply):
1. Unplug the Mains/AC Power cord and connect a wire
between the two pins of the Mains/AC Power plug.
2. Set the Mains/AC Power switch to the “on” position
(keep the Mains/AC Power cord unplugged!).
3. Measure the resistance value between the pins of the
Mains/AC Power plug and the metal shielding of the
tuner or the aerial connection on the set. The reading
should be between 4.5 MΩ and 12 MΩ.
4. Switch “off” the set, and remove the wire between the
two pins of the Mains/AC Power plug.
Check the cabinet for defects, to prevent touching of any
inner parts by the customer.
3.2 Warnings
All ICs and many other semiconductors are susceptible to
electrostatic discharges (ESD w). Careless handling
during repair can reduce life drastically. Make sure that,
during repair, you are connected with the same potential as
the mass of the set by a wristband with resistance. Keep
components and tools also at this same potential.
Be careful during measurements in the high voltage
section.
Never replace modules or other components while the unit
is switched “on”.
When you align the set, use plastic rather than metal tools.
This will prevent any short circuits and the danger of a
circuit becoming unstable.
3.3 Notes
3.3.1 General
Measure the voltages and waveforms with regard to the
chassis (= tuner) ground (H), or hot ground (I), depending
on the tested area of circuitry. The voltages and waveforms
shown in the diagrams are indicative. Measure them in the
Service Default Mode with a colour bar signal and stereo
sound (L: 3 kHz, R: 1 kHz unless stated otherwise) and
picture carrier at 475.25 MHz for PAL, or 61.25 MHz for
NTSC (channel 3).
Where necessary, measure the waveforms and voltages
with (D) and without (E) aerial signal. Measure the
voltages in the power supply section both in normal
operation (G) and in stand-by (F). These values are
indicated by means of the appropriate symbols.
3.3.2 Schematic Notes
All resistor values are in ohms, and the value multiplier is
often used to indicate the decimal point location (e.g. 2K2
indicates 2.2 kΩ).
Resistor values with no multiplier may be indicated with
either an “E” or an “R” (e.g. 220E or 220R indicates 220 Ω).
All capacitor values are given in micro-farads (μ=× 10
-6
),
nano-farads (n 10
-9
), or pico-farads (p 10
-12
).
Capacitor values may also use the value multiplier as the
decimal point indication (e.g. 2p2 indicates 2.2 pF).
An “asterisk” (*) indicates component usage varies. Refer
to the diversity tables for the correct values.
The correct component values are listed on the Philips
Spare Parts Web Portal.
3.3.3 Spare Parts
For the latest spare part overview, consult your Philips Spare
Part web portal.
3.3.4 BGA (Ball Grid Array) ICs
Introduction
For more information on how to handle BGA devices, visit this
URL: http://www.atyourservice-magazine.com
. Select
“Magazine”, then go to “Repair downloads”. Here you will find
Information on how to deal with BGA-ICs.
BGA Temperature Profiles
For BGA-ICs, you must use the correct temperature-profile.
Where applicable and available, this profile is added to the IC
Data Sheet information section in this manual.
3.3.5 Lead-free Soldering
Due to lead-free technology some rules have to be respected
by the workshop during a repair:
Use only lead-free soldering tin. If lead-free solder paste is
required, please contact the manufacturer of your soldering
equipment. In general, use of solder paste within
workshops should be avoided because paste is not easy to
store and to handle.
Use only adequate solder tools applicable for lead-free
soldering tin. The solder tool must be able:
To reach a solder-tip temperature of at least 400°C.
To stabilize the adjusted temperature at the solder-tip.
To exchange solder-tips for different applications.
Adjust your solder tool so that a temperature of around
360°C - 380°C is reached and stabilized at the solder joint.
Heating time of the solder-joint should not exceed ~ 4 sec.
Avoid temperatures above 400°C, otherwise wear-out of
tips will increase drastically and flux-fluid will be destroyed.
To avoid wear-out of tips, switch “off” unused equipment or
reduce heat.
Mix of lead-free soldering tin/parts with leaded soldering
tin/parts is possible but PHILIPS recommends strongly to
avoid mixed regimes. If this cannot be avoided, carefully
clear the solder-joint from old tin and re-solder with new tin.

Other manuals for Philips 32PFL5404H/12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Philips 32PFL5404H/12 and is the answer not in the manual?

Philips 32PFL5404H/12 Specifications

Picture and Display IconPicture and Display
aspect ratioWidescreen
brightness450 cd/m²
response time5 ms
viewing angle178º (H)/178º (V)
diagonal screen size32 inch / 81 cm
panel resolution1366 x 768p
Supported Display Resolutions IconSupported Display Resolutions
computer formats640 x 480 60 Hz, 800 x 600 60 Hz, 1024 x 768 60 Hz, 1360 x 768 60 Hz, 1920 x 1080 60 Hz
video formats480i 60 Hz, 480p 60 Hz, 576i 50 Hz, 576p 50 Hz, 720p 50, 60 Hz, 1080i 50, 60 Hz, 1080p 24, 50, 60 Hz, 1080p 24, 25, 30 Hz
Sound IconSound
output power (RMS)2 x 10 W
sound systemNicam Stereo
Power IconPower
ambient temperature5°C to 35°C
mains power220–240 V, 50 Hz
power consumption (typical)83 W
standby power consumption0.15 W
Weight and Dimensions IconWeight and Dimensions
set dimensions810 x 519 x 95 mm
set dimensions with stand810 x 570 x 230 mm
weight including packaging16 kg
product weight10 kg
product weight with stand13 kg
box dimensions981 x 651 x 199 mm
VESA wall mount compatible200 x 200 mm

Related product manuals