29
OPERATION
Safe Operating Precautions
Before Starting the Engine
1. Ensure the generator is away
from the fueling source.
2. The generator will vibrate
during operation. Place the
generator in a dry location and
on a flat, level surface.
3. Unplug all power cords and
extension cords from the
generator.
4. Engage the wheel locks if they
are installed.
Starting the Engine
1. Ensure the generator is away from the fueling source.
2. Unplug all power cords and extension cords from the generator.
3. Position the fuel valve lever to ON.
4. Position the SMART throttle switch to
OFF.
5. For a cold engine start,
position the choke knob
to CLOSE. To restart a
warm engine, leave the
choke knob in OPEN.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.
NEVER use inside a home
or garage. EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
ON
CLOSED OPEN