8 . 4 C o nt r o l U nit Er r o r C o d e s ( 9 4 5 0 S p o r t / P 9 4 5 a nd 9 5 5 0 S p o r t / P 9 5 5 )
Thecontrolunitwilldisplayoneoftendifferenterrorcodestoindicatespecicproblemswitheitherthecontrolunitor
mechanically with the cleaner.
• To remove an error code after troubleshooting, press any key and the control box turns off.
• If an error code is displayed and no key pressed, the screen goes into standby mode after 10 minutes of inactivity.
Press any key to turn the screen back on.
• When an error is detected, programming for the control unit is temporarily suspended. The button is
turned off.
Press and hold the
button to clear the error code and reactivate current programming.
Er r o r C o d e C a u se S o lu t io n
1
2
3
(1) Pump short-circuit.
(2) Right side traction motor
short-circuit
(3) Left side traction motor
short-circuit
Check for any small debris or cable stopping
brushes from turning freely.
Check the connector pins in the power cable
for corrosion or a bent pin.
Turn each wheel one quarter turn in one
direction repeatedly until rotation is smooth and
not catching, then repeat turning wheel in the
opposite direction until rotation is smooth.
If problem is not resolved through
troubleshooting, contact Polaris Technical
Support at (USA) 1-800-822-7933.
4
Pump motor overconsumption Check for small debris or hair in the fan.
Clean the lter canister.
5
6
(5) Right side drive motors
overconsumption
(6) Left side drive motors
overconsumption
Check for any small debris or hair and that the
cable is not caught, stopping brushes from
turning freely.
Turn each wheel one quarter turn in one
direction repeatedly until rotation is smooth and
not catching, then repeat turning wheel in the
opposite direction until rotation is smooth.
7
8
(7) Cleaner oats on the surface.
(8) Cleaner is turned on and running
out of water.
Turn cleaner power off, then submerge cleaner
according to correct procedure.
9
NOT A CLEANER ERROR End of cycle status code. Cleaner function is
normal. No action required.
10
Cleaner and control box
communication error.
Turn cleaner power off then back on to restart
the program.
Check connection of the oating cable on the
control box.
Check the connector pins in the power cable
for corrosion or a bent pin.
If problem is not resolved through
troubleshooting, contact Polaris Technical
Support at (USA) 1-800-822-7933.

Table of Contents

Other manuals for Polaris P935

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris P935 and is the answer not in the manual?

Polaris P935 Specifications

General IconGeneral
BrandPolaris
ModelP935
CategorySwimming Pool Vacuum
LanguageEnglish

Related product manuals