RADWIN2000CPlusUserManual Release3.5.70 E‐5
ConsiderationsforChangingAntennaParameters ChapterE
Theinequality(*)aboveisalwayssatisfiedbythesysteminaccordancewiththerelevant
regulation.
Thepreciserelationshipbetweentheitemsininequality(*)isasfollows:
• RequiredTxPower(perradio)willbeadjusteddowntothelesserofthevalueentered
andmaxAvailableTxPower
• TxPower(system)ismaxAvailableTxPower+3(for2radios)
• MaxEIRPismaxRegEIRP.
• EIRPismaxAvailableTxPower+AntennaGain‐CableLoss