V-09 05/2014 - 10 -
Because of safety reasons table units shall only be
installed on original stands of the manufacturer. In
this case the maximum rack height is 1600 mm
(63")
If Gas units are installed on a table or on the kitchen
floor (combi duo) then:
a) press the retaining plates (ET-No.:12.00.519) into
the lower part of the pedestal and fasten with the
enclosed nuts.
b) the plate must be fitted to the surface using either
screws and dowels or studs
and nuts or the special adhesive. pic. 1
plates are not included in the scope
of supply
Attention: The center height of the drain pipe is 3
1/2” (88 mm). When installing combi duo
observe the drain height of the bottom
unit.
Stands of gas appliances must be fixed to the floor
using the fixing set part no.: 8700.0317 either with
screws and dowels, or with the special adhesive
supplied unless unit is connected using AGA/CGA
approved flexible connections. pic. 2
Fixing set is not included in the scope of supply
Slide the stand into the fixing brackets and level it.
Place the unit on the stand. The feet of the unit
must be secured by means of the
locating pins of the stand pic. 3
Ensure that the unit is level pic. 4
Attention: When Installing a Combi Duo observe the
height of the drain pipe
.
Installation type 6x1/1, 6x2/1, 10x1/1, 10x2/1 GN
+_ 10mm
A 6x1/1 /10x1/1 GN: 745,5mm (29 3/8")
6x2/1 10x2/1 GN: 965,5mm (38")
64,5mm
2 5/8"
64,5mm
2 5/8"
A
5006.0213
2
+_ 10mm
3
4
1