24 RCM Dry Manure/Litter Setup Guide
TRIGGER WEIGHT
When the scale reaches the weight set in the Trigger Weight field, clean out mode will begin. Set the Trigger
Weight to the scale reading when the opening to the beaters or spinners is no longer completely covered.
CLEANOUT DURATION
This value is used to control how aggressively the apron will speed up once the trigger weight is achieved.
The steeper the angle of the material left in the spreader when the trigger weight is reached, a lower duration
value should be used. If the angle of the material left in the spreader is more gradual, a higher duration value
should be used. The default value is 15 and may be adjusted by the operator based upon the behavior of the
material being applied.
GATE HEIGHT SENSOR CALIBRATION
To access settings for Gate Height Calibration, navigate to the Rate Sensor Setup Page:
1. From the RCM home page, select the “Tools” button along the right side of the page.
2. Select the “System Settings” tab and then the “Rate Sensor Setup” button.
FIGURE 5. Setup Rate Sensor Page
3. Select the "Gate Height Sensor Cal" button.
4. Select "Custom" from the drop down list.
RCM
Menu
Tools Menu System
Settings
UT Menu
Rate Sensor
Setup

Other manuals for Raven RCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven RCM and is the answer not in the manual?

Raven RCM Specifications

General IconGeneral
BrandRaven
ModelRCM
CategoryControl Unit
LanguageEnglish

Related product manuals