2.9Locationandmounting
Siterequirements
Whenplanningtheinstallation,takethefollowingsiterequirements
intoaccount.
AISrequirement
ThisproductisNOTapprovedforuseinhazardous/ammable
atmospheres.DoNOTinstallinahazardous/ammableatmosphere
(suchasinanengineroomornearfueltanks).
TheAISunitmustbettedinalocationwhereitisnotlikelytobe
steppedonortrippedover,andwhich:
•Iscloseenoughtoallowconnectiontothevessel’sVHFwiththe
3ft(1m)RFcablesupplied.
•Isatleast3ft(1m)fromanengine,compassoranymagnetic
device.
•Hasatleast6in(100mm)ofclearspacebelow,toallowaccess
forcablingandadequatecablebends.
•Ismaintainedatatemperaturebetween-15°C(5°F)and+55°C
(130°F).
Unitdimensions
ItemDescription
A.
150mm(5.90in)
B.
167mm(6.57in)
C.50mm(1.95in)
D.
20.3mm(0.8in)
E.
99.5mm(3.92in)
F.
54mm(2.12in)
Mounting
FittingtheAISunit
Note:T oensurewaterresistancetheunitmustbemounted
verticallywiththeconnectorsfacingdown.
26AIS350/AIS650Installationinstructions