ItemDescription
1Nut
2Springwasher
3
W
asher
4Additionaldrainwire
5Productadditionalgroundpoint
Connectoneendoftheadditionaldrainwiretoyourproduct.T olocatetheadditionalgrounding
pointonyourproduct,refertotheConnectionsillustrationinthisdocument.
Connecttheotherendoftheadditionaldrainwiretothesamepointasthepowercabledrain
wire(shield).Thiswillbeeitherthevessel'sRFgroundpoint,oronvesselswithoutanRFground
system,thenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminalconnectedtothevessel'sground;or
Floating,withneitherbatteryterminalconnectedtothevessel'sground.
Ifseveralitemsrequiregrounding,theymayfirstbeconnectedtoasinglelocalpoint(e.g.withina
switchpanel),withthispointconnectedviaasingle,appropriately-ratedconductor,tothevessel’s
commonRFgroundpoint.
Implementation
Thepreferredminimumrequirementforthepathtogroundisviaaflattinnedcopperbraid,with
a30Arating(1/4inch)orgreater.Ifthisisnotpossible,anequivalentstrandedwireconductor
maybeused,ratedasfollows:
forrunsof<1m(3ft),use6mm
2
(#10AWG)orgreater.
forrunsof>1m(3ft),use8mm
2
(#8AWG)orgreater.
Inanygroundingsystem,alwayskeepthelengthofconnectingbraidorwiresasshortaspossible.
References
ISO10133/13297
BMEAcodeofpractice
NMEA0400
Cablesandconnections53

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine CP370 and is the answer not in the manual?

Raymarine CP370 Specifications

General IconGeneral
BrandRaymarine
ModelCP370
CategorySonar
LanguageEnglish

Related product manuals