EasyManuals Logo
Home>Raymarine>Monitor>E70141

Raymarine E70141 User Manual

Raymarine E70141
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
10.3Usercalibrationi40Wind
Calibrationproceduresaredependantoninstrument
displayvariant.
Usercalibrationoptionsinclude:
WindAngledisplayresponseDictatesthe
rateatwhichtheinstrumentdisplayrespondsto
changesinwindangledata.
WindSpeeddisplayresponseDictatesthe
rateatwhichtheinstrumentdisplayrespondsto
changesinwindspeeddata.
UnitsforwindspeedreadingsAssignstheunit
ofmeasureusedforwindspeedrelatedreadings.
LinearizationPerformswindtransducer
linearization.
AlignmentAlignswindtransducertovessel
heading.
Note:*Thesesettingsareonlyavailableonunits
whentheinstrumentstatussettoMaster(see
IntermediateCalibrationfordetailsofchangingthe
displaytobeMasterorRepeater).
Calibratingwind
Youwillneedtobeunderway,withsufcientspace
toturninalargeslowcircleunhindered.Conditions
shouldbecalm(i.e.aslightsea)andasteady
breeze.Trytoensurethevesselisnotrollingor
pitchingtoomuch.
Duringnormaloperation:
1.SimultaneouslypressandholdtheDownand
Actionbuttonsfor2secondstodisplaytheUser
Calibrationpage.
10
15
20
25
30
35
40
45
50
55
60
5
2
+
D12 4 20 -1
2.PresstheActionbuttontodisplaythesetWind
AngleResponsepage.
CAL
D12 4 17 -1
3.UsetheUpandDownbuttonstoadjustthewind
angleresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
4.PresstheActionbuttontodisplaytheWind
SpeedResponsepage.
CAL
D12 4 18 -1
5.UsetheUpandDownbuttonstoadjustthewind
speedresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
6.PresstheActionbuttontodisplaytheWind
SpeedUnitspage.
CAL
D12 4 19 -1
7.UsetheUpandDownbuttonstoselectthe
requiredunitofmeasurementforwindspeed
readings.
Theunitsofmeasureavailableforwindspeed
readingsare:
KTSKnots(default)
M/SMetersPerSecond
8.PresstheActionbuttontodisplaytheLinearize
Transducerpage.
CAL
D12 4 05 -1
Note:If5pdisdisplayedonthelinearize
transducerpagethewindspeedisoutsideofthe
rangesuitableforlinearization.
9.Keepthevesselspeedbelow2ktsandbeginto
turnthevesselinacircle.
10.PresstheUpbuttontobeginlinearization.
11.Youwillberequiredtoperformaminimumof2
completecircles.
x 2
D12415-2
Analarmwillsounduponsuccessfulcompletion.
12.Sailthevesseldirectlyintothewind.
13.PresstheActionbuttontodisplaytheAlign
Transducerpage.
CAL
D12 4 16 -1
14.UsetheUpandDownbuttonstoadjustthevalue
untilthewindanglepointerissettozero.
CAL CAL
D13079-1
15.T osaveyoursettingsandreturntonormal
operationfromanypage,simultaneouslypress
andholdtheDownandActionbuttonsfor2
seconds.
i40Wind59

Table of Contents

Other manuals for Raymarine E70141

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine E70141 and is the answer not in the manual?

Raymarine E70141 Specifications

General IconGeneral
BrandRaymarine
ModelE70141
CategoryMonitor
LanguageEnglish

Related product manuals