B6000 BOILER MANAGEMENT SYSTEM START-UP DATA
SYSTEM SETTINGS ENTERED ON DATE:_____________________________________
Temperature Scale
°F or °C
Standard
Set _____ Deg. Ratio _____ : 1 Rise _____ Deg.
System Water Temp. @ Oc Reset Ratio-Outdoor: System Design Temp. Diff.
Default Value 100°F (38°C) Default Value: 1.0:1 Default Value: 20°F (7°C)
Select Set Optional
Day _____ Deg. Nite_____ Deg. Ratio _____:1 Rise _____ Deg.
System Temps @ Oc Reset Ratio System Design Temp. Rise
Default Value Default Value: Default Value: Default Value:
100°F (38°C) 90°F (32°C) 1 .0:1 20°F (7°C)
Universal
Step _____ % O/C_____Deg. O/Cdb _____Deg. C Band _____ Deg.
Valve Opening Outdorr Cutoff Outdoor Cutoff Control Band
Default Value: Default Value: Deadband Default Value:
5% 65 degs. Default Value: 4 Deg 3 Deg.
Lead _____ # of Boilers _____
Indicates Lead Boiler Number of Boilers in system.
Select Set Optional
Lead Change hrs. _____
Lead boiler will change after selected no. of hours.
Universal
Pump Delay _____ Min. Ign Time _____ Sec.
Delay off pump timing. Ignition lockout timing.
Default Value: 3 min. Default value: 15 seconds.
Select Set Option
____________ __________ ____________________ _______________
Time of Day AM or PM Day of Week Set-back- Off or On
Default Value: Monday Default Value: Off
Period 123456
Set-Back On Off On Off On Off On Off On Off On Off
Monday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Tuesday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Wednesday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Thursday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Friday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Saturday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Sunday ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
Proportional Integral Derivative
____________________ ____________________ ____________________
Pconst Wait (Integral) Derivative
V___________________ Version # of Software