Programmable Features
26
01 Utility Priority and Battery Priority
The PCL inverter charger series is fully programmable. You may change the respective
parameter by going to the Program Number listed below
Program
Setting Programs:
Description Selectable option
00
Exit setting mode, go back to main menu
1. Hold down to enter Parameter setting menu.
Cycle through the menu
Cycle through the menu
2. Tap to change/confirm setting in parameter setting menu
Function Keys
When setting Frequency, Output Voltage, The Charge Current, and AC input voltage
range, you must shut down the inverter charger completely for the changes to take effect
NOTE
Utility Priority
Battery Priority
The default setting is Utility Priority (Ut1). Under this setting, once the inverter charger is
connected to the utility, it will power the loads using the electricity from shore supply.
The inverter charger will start charging the battery bank using the AC source, if necessary.
In case of power outage, the system automatically switches to battery-powered mode.
The second setting is Battery Priority (SbU). Under this setting the inverter charger will
provide power using the connected battery bank even when it detects an AC source.
When the battery voltage reaches the low voltage set-point in Program 12, the inverter
charger will power the loads using the connected AC source but will not charge the battery
bank.