Revision 2.6 Page 19 of 53
Intuitive Mercury 6-5M Controller with TDB
www.resourcedm.com
Warning
Please Note
The specifications of the product detailed on this
Set-Up Guide may change without notice. RDM
Ltd. shall not be liable for errors or for incidental
or consequential damages, directly and indirectly,
in connection with the furnishing, performance or
misuse of this product or document.
Toolbox Menu Items
Selection tool
Building blocks (right click for sub menu's)
Static Text
Zoom in/out
Shortcut block
Setting Block
Online Mode
Run Simulation
The floating toolbox also shows the current number of blocks used in the PLC program.
Selection Tool
Left click on this icon to select the "selection tool", use this (left click and hold) to move items around on the workspace (release).
Building Blocks ?
Selection of building blocks is achieved by right clicking on the icon and rolling the mouse over one of the sub menu items and then left click on
the item. Left clicking on the workspace will drop the item. Further left clicks will give more of the same item. To select another item, repeat the
procedure. Initially this icon will show?” until an item is selected.
The sub-menu choices are: -
IO
o Analog In
o Analog Out
o Digital In
o Digital Out
o Network Analogue In
o Network Digital In
o Pulse Input
o GP Timer 3 Block
o Defrost Signal
o State Block
o Humidistat Display Block
o Mercury Display Block
Logic
o 2-AND Block
o 3-AND Block
o 4-AND Block
o 2-OR Block
o 3-OR Block
o 4-OR Block
o NOT Block
o XOR Block
Mathematical
o Add
o Subtract
o Multiply
o Divide
o Absolute
o X Power Y
o Min Block
o Max Block
o Equals Block
o Less-Than Block
o Greater-Than Block
o Less-Than-Or-Equals Block
o Greater-Than-Or-Equals Block
o 2-Average Block
o 3-Average Block
o 4-Average Block
o Limit Block
o In Range Block
o Min/Max/Avg Block
o Filter Block
o Accumulator
o Algebra
Time
o Delay Timer
o Pulse Timer
o Heartbeat
o Run On Block
o Run Hours Block
o Change Over Block
o Match Date Block
o Date Time Block
o Summer Winter
o Daylight Block
o Time Block
o Schedule Block
o Day of Week
Functional
o Alarm Block
o Analog Switch
o Analog Store
o Pulse Counter
o D-Type Latch
o SR Latch
o Digital Edge Block
o Analogue Edge Block
o Reverse On/Off
o Direct On/Off
o Direct PID
o Reverse PID
o Levels Block
o P to T Block
o Comfort Block
o Offline Indicator
Diagnostic
o Analogue
Display
o Digital Display
Custom
o Custom Blocks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Resource Data Management PR0760-TDB and is the answer not in the manual?

Resource Data Management PR0760-TDB Specifications

General IconGeneral
BrandResource Data Management
ModelPR0760-TDB
CategoryController
LanguageEnglish

Related product manuals