Service
Manual
C221 CD
Player
nÄ/ox
4.2.7 DIP
switches
(SW1)
The B
DIP switches
are used for the internal configuration
of
the
CD
player.
The factory
presets
all
switches to the
ON
position
which
corresponds
to
log.
"1".
DIP switches
S'1
to 54 define
the
equipment
address
in serial bus
mode.
51-
ADRO
52
-
ADR1
53
-
ADR2
54
-
ADR3
Group
address
0
Equipment
1
address
2
3
4
5
6
7
8
I
10
11
12
13
14
15
S3
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
-
-
"oFF"
The factory sets the equipment address
to 15. Address 0 is
reserved as
the
group
address. All units, regardless of
their
presetting,
respond
to commands that contain this address.
DIP switches 55
to SB define
the
power-on
state
of the CD
player.
The
following functions
are
preset:
55
-
REMAINING
TIME
56
-
FADER
ENABLE
57
-
AUTO PAUSE
58
-
AUTO CUE
35