Air
Model Features/Physical Data & Specifications
RGPQ Series
4
• Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
• Low profile “34 inch” design is lighter and easier to handle,
and leaves room for optional equipment.
• Convertible from upflow to horizontal left or right without field
conversion.
• Left or right side gas and electric inlet connections with quick,
simple change.
• Direct spark ignition models equipped with remote sense and
feature an integrated board with humidifier and electronic air
cleaner hookups.
• Insulated blower compartment, a two stage gas valve and a
specially designed two speed draft inducer motor make it one
of the quietest furnaces on the market today.
• Pre-paint galvanized steel cabinet.
• Molded permanent filter.
• Grab-holes in doors to aid in easy door removal and
replacement.
• Compatible with single or two-stage thermostat. (For optimal
performance two-stage thermostat recommended.)
• A variety of cooling coils and plenums designed to use with
Rheem Classic
®
Series 2-Stage gas furnaces are available as
optional accessories.
Model Features
Physical Data and Specifications—Downflow Models
U.S. and Canadian Models
MODEL NUMBERS
RGPQ- SERIES
05EAUER
05NAUER
07EAMER
07NAMER
Standard Filter–In.
[mm]
15
3
/4 x 25
[400 x 635]
15
3
/4 x 25
[400 x 635]
High Inpu
t–BTU–B
TU/Hr [kW] ➁
50,000 [15] 75,000 [22]
Heating Capa
city–BTU
/Hr [kW] ➀
40,900 [12] 61,280 [18]
Blower (D x W) [mm]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
Motor H.P.–[W]
Speeds–Type
1
/2 [373]
4-PSC
1
/2 [373]
4-PSC
Motor Full Load Amps 7.1 7.1
Heating Speed–High Fire MED-LOW MED-HIGH
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
1200
[566]
1200
[566]
Max. E.S.P. (In. W.C.) [kPa] 0.5 [.12] 0.5 [.12]
Temperature Rise Range °F
High Input [°C]
25-55
[13.9-30.6]
30-60
[16.7-33.3]
Max. Outlet Air Temp. °F
[°C]
155
[68.3]
165
[73.9]
Approx. Shipping Weight (Lbs.)
[kg]
85
[39]
105
[48]
Return Air Cabinets (Opt.) RXGR-
Filter Size–In.
[mm]
C14B
(2) 12 x 16
[305 x 406]
C17B
(2) 12 x 16
[305 x 406]
AFUE ➀
80.0% 80.0%
Low Input–BTU/Hr [kW] 35,000 [10] 52,500 [15]
Heating Capacity–BTU/Hr [kW] 28,000 [8] 41,600 [12]
07EAMGR
07NAMGR
10EAMER
10NAMER
10EBRJR
10NBRJR
12EARJR
12NARJR
15
3
/4 x 25
[400 x 635]
15
3
/4 x 25
[400 x 635]
19
1
/4 x 25
[489 x 635]
22
3
/4 x 25
[578 x 635]
75,000 [22] 100,000 [29] 100,000 [29] 125,000 [37]
52,500 [15] 70,000 [20] 70,000 [20] 87,500 [25]
61,410 [18] 81,470 [23] 81,340 [23] 101,660 [29]
41,600 [12] 56,000 [16] 56,000 [16] 70,080 [20]
11 x 7
[279 x 178]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
1
/2 [373]
4-PSC
3
/4 [559]
4-PSC
3
/4 [559]
4-PSC
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-HIGH MED-HIGH
MED-HIGH HIGH HIGH HIGH
1600
[755]
1200
[566]
2000
[944]
2000
[944]
0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12]
25-55
[13.9-30.6]
45-75
[25-41.7]
30-60
[16.7-33.3]
35-65
[19.4-36.1]
155
[68.3]
190
[87.7]
170
[76.6]
180
[82.2]
105
[48]
115
[52]
120
[54]
140
[63]
C17B
(2) 12 x 16
[305 x 406]
C17B
(2) 12 x 16
[305 x 406]
C21B
(2) 20 x 16
[508 x 406]
C24B
(2) 24 x 16
[610 x 406]
80.0% 80.0% 80.0% 80.0%
15EARJR
15NARJR
22
3
/4 x 25
[578 x 635]
150,000 [44]
105,000 [30]
121,920 [35]
84,000 [24]
11 x 10
[279 x 254]
3
/4 [559]
4-PSC
9.5
MED-HIGH
HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
190
[87.7]
150
[68]
C24B
(2) 24 x 16
[610 x 406]
80.0%
Heating–Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .15 [.037] .20 [.05] .20 [.05]
Heating Speed–Low Fire LOW MED-LOW LOW LOW LOW LOW LOW
Temperature Rise Range °F
Low Input [°C]
20-50
[11.1-27.8]
25-55
[13.9-30.6]
15-45
[8.3-25.0]
35-65
[19.4-36.1]
25-55
[13.9-30.6]
30-60
[16.7-33.3]
40-70
[22.2-38.9]
NOTES:All models are 115V, 60HZ, 1Ø. Gas connection size for all models is
1
/2" [12.7 mm] N.P.T.
➀ In accordance with D.O.E. test procedures.
➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
[ ] Designates Metric Conversions