3.0 UNIT SPECIFICATIONS
General Information
Unit Specications
drop. Follow industry best practices for installation.
Installation and commissioning of this equipment
is to be performed by trained and qualified HVAC
professionals. For technical assistance, contact your
Distributor Service Coordinator.
2.5 Importance of Proper Indoor/
Outdoor Match-Ups
To assure many years of reliable operation and
optimum customer comfort and to assure the outdoor
unit warranty remains valid, an air-handler model or
indoor coil/furnace combination should be selected
that is properly matched to the outdoor unit. This is
especially critical for heat pump systems to assure
proper refrigerant charge balance between the cooling
and heating modes. The recommended approach is to
select an air-handler or indoor coil and gas furnace that
has an AHRI match with the outdoor unit. Refer to the
AHRI directory at www.ahridirectory.org to confirm the
air-handler and outdoor unit are a certified combination
in the AHRI Directory.
2.6 Checking Product Received
Upon receiving unit, inspect it for any shipping damage.
Claims for damage, either apparent or concealed,
should be filed immediately with the shipping company.
Check model number, electrical characteristics, and
accessories to determine if they are correct. Check
system components (indoor coil, outdoor unit, air
handler/furnace, etc.) to make sure they are properly
matched.
2.7 Compressor Break-In Notice
Prior to agency testing, system must be operated for 20
hours at 11F [46.C] outdoor ambient temperature
with 80ºF [26.7ºC] dry bulb 75ºF
[23.9ºC] wet bulb indoor ambient temperature to break
the compressor in.
3.1 Model Number Nomenclature and Available Models
R P 18
C
Y
24 A J V C A
MINOR SERIES
CONTROLS
TYPE
1 =- 1 STAGE
2 = 2 STAGE
3 =- 3 STAGE
V = FULLY VARIABLE
VOLTAGE
J = 1PH 208-230 VAC 60 Hz
MAJOR
SERIES
CAPACITY
24 = 24000 BTU/HR
36 = 36000 BTU/HR
48 = 48000 BTU/HR
60 = 60000 BTU/HR
REFRIGERANT
Z= R- 410A
Y = R- 454B
W = FUTURE REFRIGERANT
REGION
C = COLD CLIMATE
SEER2
PRODUCT CATEGORY
P = HEAT PUMP
D = SIDE DISCHARGE HEAT PUMP
A = AIR CONDITIONER
BRAND
R = RHEEM
U = RUUD
S = SURE COMFO
ML = MAINLINE
RT
Table 1: Available Models
Heat Pumps Air Conditioners
(-)P18AZ24AJVCA (-)A18AZ24AJVCA
(-)P18AZ36AJVCA (-)A18AZ36AJVCA
(-)P18AZ48AJVCA (-)A18AZ48AJVCA
(-)P18AZ60AJVCA (-)A18AZ60AJVCA