EasyManuals Logo
Home>Rigol>Test Equipment>MSO7024

Rigol MSO7024 User Manual

Rigol MSO7024
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #320 background imageLoading...
Page #320 background image
RIGOL Chapter 18 Store and Load
18-8 MSO7000/DS7000 User Guide
Number of
Points
A 4-byte integer, indicating the number of waveform points in
the data.
Count
A 4-byte integer, indicating the number of hits at each time
interval during waveform recording when using a certain
sample mode (e.g. Average) to create the waveforms. For
example, when averaging, a count of 4 indicates that each
waveform data point in the waveform recording has been
averaged at least 4 times. The default value is 0.
X Display
Range
A 4-byte float, indicating the X-axis duration of the waveform
that is displayed. For time-domain waveforms,
it indicates the duration of time across the display. If the
value is zero, then no data has been acquired.
X Display
Origin
A 8-byte double, indicating the X-axis value at the left edge of
the screen. For time-domain waveforms, it indicates the time
at the start of the display. The value is treated as a double
precision 64-bit float point number. If the value is zero, then
no data has been acquired.
X Increment
A 8-byte double, indicating the duration between data points
on the X axis. For time-domain waveforms,
it indicates the time between points. If the value is zero, then
no data has been acquired.
X Origin
A 8-byte double, indicating the X-axis value of the first data
point in the data recording. For time-domain waveforms, it
indicates the time of the first point. The value is treated as a
double precision 64-bit float point number. If the value is
zero, then no data has been acquired.
X Units
A 4-byte integer, indicating the unit of measurement for X
values in the acquired data.
0 = Unknown
1 = Volts (V)
2 = Seconds (s)
3 = Constant
4 = Amps (A)
5 = dB
6 = Hz
Y Units
A 4-byte integer, indicating the unit of measurement for Y
values in the acquired data. The possible values are listed
above under X Units.
Date
A 16-byte character array, not used
Time
A 16-byte character array, not used
Frame
A 24-byte character array, indicating the model number and
serial number of the oscilloscope in the format:
MODEL#:SERIAL#.
Waveform
Label
A 16-byte character array that contains the label assigned to
the waveform.

Table of Contents

Other manuals for Rigol MSO7024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO7024 and is the answer not in the manual?

Rigol MSO7024 Specifications

General IconGeneral
BrandRigol
ModelMSO7024
CategoryTest Equipment
LanguageEnglish

Related product manuals