www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
GB
|
23
7. Technical data
AC motor 220 - 240 V~ 50 Hz
Nominal power S1 710 Watt
Operating mode S2 5min* 900W
Idle speed n
0
500 - 2600 min
-1
Drill chuck clamping
range
1.5 - 13 mm
Max. drill stroke 70 mm
Size of base plate 275 x 190 mm
Distance of drill-chuck to
base plate
280 mm
Weight approx. 8.1 kg
Protection class II /
Laser class 2
Laser wavelength 650 nm
Laser power < 1 mW
* After an uninterrupted operating period of 5 min-
utes, the device should be allowed to rest until its
temperature has dropped to within 2 K (2° C) of room
temperature.
The workpiece must have a minimum height of
3 mm and a minimum width of 45 mm. Make sure
that the workpiece is always secured with the
clamping device.
Noise
Sound and vibration values were measured in ac-
cordance with EN 62841.
Sound pressure level L
pA
89.6 dB(A)
Uncertainty K
pA
3 dB
Sound power level L
WA
102.6 dB(A)
Uncertainty K
WA
3 dB
Wear ear-mus.
Excessive noise can result in a loss of hearing.
The above-mentioned noise emission values were
measured in accordance with a standardised test
procedure and can be used to compare one power
tool with another.
The specied device emissions values can also be
used for an initial estimation of the load.
Warning:
• The noise emission values can vary from the speci-
ed values during the actual use of the electric tool,
depending on the type and the manner in which the
electric tool is used, and in particular the type of
workpiece being processed.
Attention: Laser radiation
Do not look into the beam
Laser class 2
Protect yourself and you environment from acci-
dents using suitable precautionary measures!
• Do not look directly into the laser beam with un-
protected eyes.
• Never look into the path of the beam.
• Never point the laser beam towards reecting sur-
faces and persons or animals. Even a laser beam
with a low output can cause damage to the eyes.
• Caution - methods other than those specied here
can result in dangerous radiation exposure.
• Never open the laser module. Unexpected expo-
sure to the beam can occur.
• The laser may not be replaced with a dierent type
of laser.
• Repairs of the laser may only be carried out by the
laser manufacturer or an authorised representa-
tive.
• Labelling and placement of warning stickers, see
g. 8 and 9.
m WARNING! This electric tool generates an elec-
tromagnetic eld during operation. This eld can im-
pair active or passive medical implants under certain
conditions. In order to prevent the risk of serious or
deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operat-
ing the electric tool.
Residual risks
Even if you use this electric power tool in accord-
ance with instructions, certain residual risks
cannot be eliminated. The following hazards may
arise in connection with the equipment’s con-
struction and layout:
• Lung damage if suitable dust protection mask is not
worn.
• Hearing damage if suitable hearing protection is
not worn.
• Damage to health resulting from hand/arm vibra-
tion if the device is used over an extended period of
time or if it is not properly operated and maintained.