12
DEUTSCH
X 2
DisplayPress KeyAction
Step
COUNTER RESET
Each number of times can be cleared.
Example : Suppose you want to clear the times of memory 1.
(Total count)
(Times memory 1 used)
INFORMATION WITH ERROR MESSAGES
If ERROR messages are displayed, follow the below instructions.
ERROR MESSAGES
EE1, EE2, EE3,
EE6, EE8, EE0
EE10, EE16
EE7
EE9
EE17
INFORMATION WITH FILTER INDICATOR
Clean the air intake filter when the FILTER indicator lights up (See page 14.). The FILTER indicator will light up
when the oven has been operated for about 200 hours in total.
To cancel FILTER indicator touch the START key (
). The oven will start to count the operation time
automatically again when the FILTER indicator is canceled.
1
CHECK
NUMBER
CHECK
NUMBER
CHECK
Choose checking mode.1
Choose the memory 1.
Clear times of using the memory 1.
Cancel checking mode.
2
3
4
NOTE:
1. To clear times of manual cooking, touch MANUAL/REPEAT key (
) at step 2 instead of NUMBER key.
To clear times of Defrost cooking, touch DEFROST key (
) at step 2 instead of NUMBER key.
2. To clear total using times, skip step 2.
Please contact your dealer or an authorized Sharp service agent because the oven
must be out of order.
Exhaust air temperature is too high. Checking that nothing is blocking the ventilation
openings or that room temperature is very hot or that oven cavity is empty during
operation. Correct, touch STOP/CLEAR key (
) and try again after a few
minutes.
Cooking time exceed the max. time. Touch STOP/CLEAR key (
) and
programme again.
Magnetron temperature is too high, touch STOP/CLEAR key (
) and try again
after a few minutes.

Other manuals for Sharp R-23AT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp R-23AT and is the answer not in the manual?

Sharp R-23AT Specifications

R-23AT

Power IconPower
AC line voltage230 V, 50 Hz, single phase
distribution line fuse/circuit breaker16 A (time lag)
AC power required2.9 kW
output power1800 W (IEC 60705)
microwave frequency2450 MHz
Capacity IconCapacity
oven capacity20 litres
cooking uniformityrotary antenna system
Weight and Dimensions IconWeight and Dimensions
outside dimensions (single oven)510 mm (W) x 335 mm (H) x 470 mm (D)
cavity dimensions330 mm (W) x 180 mm (H) x 330 mm (D)
weight33 kg

R-25AT

Power IconPower
AC line voltage230 V, 50 Hz, single phase
distribution line fuse/circuit breaker16 A (time lag)
AC power required3.15 kW
output power2100 W (IEC 60705)
microwave frequency2450 MHz
Capacity IconCapacity
oven capacity20 litres
cooking uniformityrotary antenna system
Weight and Dimensions IconWeight and Dimensions
outside dimensions (single oven)510 mm (W) x 335 mm (H) x 470 mm (D)
outside dimensions (two ovens)510 mm (W) x 670 mm (H) x 470 mm (D)
cavity dimensions330 mm (W) x 180 mm (H) x 330 mm (D)