EasyManuals Logo
Home>SICK>Accessories>TiM1 Series

SICK TiM1 Series User Manual

SICK TiM1 Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
10 Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
www.sick.com/TiM1xx
10.1 Features
Device type TiM10x TiM15x
Light source Infrared (invisible; wavelength
850nm; pulse length 2.5ns;
max. output power 500mW)
Infrared (invisible; wavelength
850nm; pulse length 2.5ns;
max. output power 1,500mW)
Laser class Laser class 1 according to EN/IEC 60825-1:2014. Complies with
21 CFR 1040.10 and 1040.11 except for deviations pursuant to
Laser Notice No. 50, dated June 24, 2007.
Aperture angle 200°
Angular resolution
Scanning frequency 14.5Hz
Working range 0.05m ... 3m 0.05m ... 10m
Sensing range with 10%
remission
At least 1.2m across enter
aperture angle
1.5 m (0° axis)
at least 2.8m across entire
aperture angle
3m (0° axis)
Sensing range diagram
0
Scanning range in m (ft)
–2
(–6.56)
2
(6.56)
–3
(–9.84)
3
(9.84)
–1
(–3.28)
1
(3.28)
Scanning range in m (ft)
–2
(–6.56)
2
(6.56)
0
Scanning range max. 3 m (9.84 ft)
Scanning range 1.2 m to 1.5 m (3.94 ft to 4.92 ft)
for objects with 10 % remission, dependent on the angle
4
(13.12)
–4
(–13.12)
–4
(–13.12)
4
(13.12)
200°
90°
–90°
100°
‒100°
Figure 12: Sensing range diagram TiM10x
Scanning range max. 10 m (32.81 ft)
Scanning range 2.8 m to 3 m (9.19 ft to 9.84 ft)
for objects with 10 % remission, dependent on the angle
200°
90°
–90°
100°
‒100°
0
Scanning range in m (feet)
Scanning range in m (feet)
0
6
(19.69)
6
(19.69)
2
(6.56)
2
(6.56)
2
(6.56)
2
(6.56)
6
(19.69)
10
(32.81)
14
(45.93)
10
(32.81)
14
(45.93)
6
(19.69)
14
(45.93)
14
(45.93)
10
(32.81)
10
(32.81)
Figure 13: Sensing range diagram TiM15x
10.2 Performance
Device type TiM10x TiM15x
Response time Typ. ≥70ms
TECHNICAL DATA 10
8020631/1DWW/2022-08 | SICK O P E R A T I N G I N S T R U C T I O N S | TiM1xx
31
Subject to change without notice

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK TiM1 Series and is the answer not in the manual?

SICK TiM1 Series Specifications

General IconGeneral
BrandSICK
ModelTiM1 Series
CategoryAccessories
LanguageEnglish