EasyManuals Logo
Home>Siemens>Controller>CPU 314

Siemens CPU 314 User Manual

Siemens CPU 314
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
Technical data of CPU 31xC
6.6 Technical data of the integrated I/O
CPU 31xC and CPU 31x, Technical Data
Manual, 01/2006 Edition, A5E00105475-06
6-51
Technical data
Connection of signal generators
For voltage measurement
possible
For current measurement
as 2-wire measuring transducer
as 4-wire measuring transducer
Possible, with external power supply
possible
for measuring resistance
with 2-conductor terminal
with 3-wire connection
with 4-wire connection
Possible, without compensation of
cable resistance
Not possible
Not possible
Linearization of the characteristics trend By software
For resistance thermometers
Pt 100
Temperature compensation No
Technical unit for temperature measurement Degrees Celsius/Fahrenheit/Kelvin
6.6.9 Analog outputs
Introduction
This chapter contains the specifications for digital outputs of CPUs 31xC.
The table includes the following CPUs:
CPU 313C
CPU 314C-2 DP
CPU 314C-2 PtP
Technical data
Table 6-15 Technical data of analog outputs
Technical data
Module-specific data
Number of outputs 2
Cable length
Shielded
Max. 200 m
Voltage, currents, potentials
Rated load voltage L+ 24 VDC
Polarity reversal protection
Yes
Electrical isolation
Between channels and the backplane bus
Yes
Between the channels
No

Table of Contents

Other manuals for Siemens CPU 314

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CPU 314 and is the answer not in the manual?

Siemens CPU 314 Specifications

General IconGeneral
BrandSiemens
ModelCPU 314
CategoryController
LanguageEnglish

Related product manuals