Technical Data
8.2 Hybrid and Sensor Cables
LDS 6
Operating Instructions, 01/2009, A5E00295894-05
87
8.2 Hybrid and Sensor Cables
Table 8- 10 General
General
Configuration hybrid cable Two optical fibers and two twisted copper wires in
one cable for 24 V DC. Single-mode optical fiber
configured at both ends with E2000 angle
connectors. Multimode optical fiber configured at
both ends with SMA connectors.
Cable sheath Oil-resistant polyurethane
Dimensions
- Diameter
- Length
< 8 mm,
up to 1 000 m
for lengths > 500 m, an external power supply
must be additionally ordered
for installations in Ex zones, non-intrinsically-safe
cables have to be spatially separated from
intrinsically-safe lines, lengths <600 m
Impact resistance 200 N/cm
Maximum tensile strength 500 N
Minimum bending radius 10 cm
Table 8- 11 Climatic conditions
Climatic conditions
Ambient temperature -40 ... +80 °C during operation
Rel. humidity < 95 % rel. humidity, above dew point