Migration from MC35 to MC35i
PRELIMINARY
Migration from MC35 to MC35i
21 of 30 12.03.03
# AT Command
25 ATS7 Set number of seconds to wait for connection completion
26 ATS8 Set number of seconds to wait for comma dial modifier
27 ATS10 Set disconnect delay after indicating the absence of data carrier
28 ATS18 Extended error report
29 ATT Select tone dialling
30 ATV Set result code format mode
31 ATX Set CONNECT result code format and call monitoring
32 ATZ Set all current parameters to user defined profile
Additional note
MC35
N/A
MC35i
If the user profile contains invalid settings for AT\Q,
AT&S, AT&D or AT&C the corresponding values will
be set to its factory default.
Related chapters: AT&F in chapter 2.35, AT&W in
chapter 2.38
33 AT&C Set circuit Data Carrier Detect (DCD) function mode
34 AT&D Set circuit Data Terminal Ready (DTR) function mode
Additional note
MC35
N/A
MC35i
Factory default is 2 if DTR is supported by the
interface, otherwise 0.
35 AT&F Set all current parameters to manufacturer defaults
36 AT&S Set circuit Data Set Ready (DSR) function mode
37 AT&V Display current configuration
Differing parameters
MC35
N/A
MC35i
+CGSMS setting listed in all configurations (with or
w/o PIN authentication, for all MUX channels)
38 AT&W Store current configuration to user defined profile
Differing parameters
MC35
AT\Qn is NOT stored to user profile.
MC35i
AT\Qn is stored to user profile.
39 AT+GCAP Request complete TA capabilities list
40 AT+GMI Request manufacturer identification
41 AT+GMM Request TA model identification
Differing result code
MC35
MC35
OK
MC35i
MC35i
OK
42 AT+GMR Request TA revision identification of software status
43 AT+GSN Request TA serial number identification (IMEI)
44 AT+ILRR Set TE-TA local rate reporting
Differing parameters
MC35
N/A
MC35i
Local data rate of 230400bps available.
45 AT+IPR Set fixed local rate
Differing parameters
MC35
N/A
MC35i
Fixed local data rate of 230400bps available.