Migration from MC35 to MC35i
PRELIMINARY
Migration from MC35 to MC35i
26 of 30 12.03.03
5.2.7 Siemens defined AT commands for enhanced functions
Table 16: Siemens defined AT commands
# AT Command
157 AT+CXXCID Display card ID (identical to AT^SCID)
158 AT^MONI Monitor idle mode and dedicated mode
Differing parameters, implementation and syntax wording
MC35
PLMN only
MC35i
PLMN is divided into MCC and MNC, differing
statuses
159 AT^MONP Monitor neighbour cell
Differing parameters
MC35
PLMN only
MC35i
PLMN is divided into MCC and MNC
160 AT^SACM Advice of charge and query of ACM and ACMmax
161 AT^SBC Battery charge and charger control
Differing parameters
MC35
<bcs>
0 No charging adapter is connected
1 Charging adapter is connected
2 Charging adapter is connected, charging in
progress
3 Charging adapter is connected, charging has
finished
4 Charging error, charging is interrupted
5 False charging temperature, charging is
interrupted while temperature is beyond allowed
range
<bcl> Battery capacity
0, 20, 40, 60, 80, 100 percent of remaining capacity
(6 steps)
0 indicates that either the battery is exhausted or
the capacity value is not available
<mpc> Average power consumption:
Value (0...5000) of average power consumption
(mean value over a couple of seconds) in mA. See
read and write command for details.
MC35i
Feature not supported – not relevant to MC35i
<bcs> Connection status of charging adapter. Not
relevant for MC35I.
0 No charging adapter is connected.
<bcl> Battery capacity. Not relevant for MC35I.
0 Indicates that no battery is available.
<mpc> Average power consumption.
0 - 5000 ME's power consumption in mA
averaged over a couple of seconds.
162 AT^SCID Display SIM card identification number
163 AT^SCKS Set SIM connection presentation mode and query SIM connection status
164 AT^SCNI List Call Number Information
165 AT^SCTM Set critical operating temperature presentation mode or query temperature
Additional parameter and different syntax wording
MC35
<temp> not available.
MC35i
<temp> Current board temperature in Celsius. The value
is comprised between lowest and upper temperature limits.
166 AT^SDLD Delete the 'last number redial' memory
168 AT^SHOM Display Homezone
169 AT^SLCD Display Last Call Duration
170 AT^SLCK Facility lock
172 AT^SM20 Set M20 Compatibility
173 AT^SMGL List SMS messages from preferred storage
174 AT^SMGO Set or query SMS overflow presentation mode or query SMS overflow
177 AT^SMSO Switch off mobile station
178 AT^SMGR Read SMS message without set to REC READ
179 AT^SNFA Set or query microphone attenuation
180 AT^SNFD Set audio parameters to manufacturer default value
181 AT^SNFI Set microphone path parameters