EasyManuals Logo
Home>Siemens>Network Router>SCALANCE X-200 Series

Siemens SCALANCE X-200 Series User Manual

Siemens SCALANCE X-200 Series
Go to English
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Connection
5.2 Signaling contact
SCALANCE X-200
Compact Operating Instructions, 12/2010, A5E00813159-11
83
5.2 Signaling contact
Signaling contact
The signaling contact (relay contact) is a floating switch with which error/fault states can be
signaled by breaking the contact.
The signaling contact is connected to a 2-pin plug-in terminal block.
Exception:
The signaling contact on the SCALANCE X204 IRT PRO and SCALANCE X202-2P IRT
PRO is connected using a 5-pin b-coded M12 socket.
IE Switches X-200 SCALANCE X204 IRT PRO,
SCALANCE X202-2P IRT PRO,
SCALANCE X201-3P IRT PRO
Pin number Assignment Pin number Assignment
Pin 1 F1 Pin 1 F1
Pin 2 F2 Pin 2 n. c.
- - Pin 3 n. c.
- - Pin 4 F2
- - Pin 5 n. c.
The following errors/faults can be signaled by the signaling contact:
The loss and the establishment of a link on a monitored port.
The failure of one of the two redundant power supplies.
The loss of the connection to the controller in PROFINET IO mode.
The redundancy manager signals an error
Note
SCALANCE X204 IRT PRO, SCALANCE X202-2P IRT PRO and SCALANCE X201-3P
IRT PRO have no redundant power supply
Incompatible C-PLUG was inserted.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-200 Series and is the answer not in the manual?

Siemens SCALANCE X-200 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-200 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals