Options 11.98
9-4 ENGLISH Siemens AG 6SE7087-6AC85-0AA0
Common Rectifier Operating instructions
Current input of DC 24V power supply:
The figures are required in addition to the 1A consumed
by the basic unit.
(In case of size B, the demand of the basic unit
increases from 0,5A to 1A, owing to the fan required).
9.3 Power Supply
A SITOP power supply as described in Catalog KT10 is recommended for the common rectifier (connector X9).
9.4 Actual-current sensing module
Z = K91
Order-No. for retrofit assembly: 6SE7090-0XC85-1TD0
Unit Jumper I
rated output
R
i total
Size
[A] [Ω]
E J14 605 33,222
J13 536 37,507
J12 463 43,432
J11 420 47,886
J10 375 53,647
J9 354 56,849
J8 270 74,557
J7 235 85,677
J6 222 90,720
J5 173 116,421
J4 142 141,887
B and C J3 94 214,464
J2 86 234,523
J1 72 280,230
keine 41 492,381
Table 9.6 Jumpers for actual-current sensing module
Boards Current drain (mA)
24V DC supply
CB1 190
CBP 150
CB2 100
CBC 100
SCB1 50
SCB2 150
T100 550
T300 without tacho 620
Table 9.5 Current drain of the option boards