EasyManuals Logo

Siemens SINAMICS G120P PM330 User Manual

Siemens SINAMICS G120P PM330
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Basic safety instructions
1.5 Residual risks of power drive systems
Power Module PM330
Hardware Installation Manual, 10/2016, A5E32844552B AD
13
1.5
Residual risks of power drive systems
When assessing the machine- or system-related risk in accordance with the respective local
regulations (e.g. EC Machinery Directive), the machine manufacturer or system installer
must take into account the following residual risks emanating from the control and drive
components of a drive system:
1. Uncontrolled motion of the driven machine or system components during commissioning,
operation, maintenance and repair caused by, for example:
Hardware and/or software errors in the sensors, control system, actuators and cables
and connections
Response times of the controller and drive
Operation and/or environmental conditions outside the specification
Condensation/conductive pollution
Parameterization, programming, cabling, and installation errors
Use of wireless devices/mobile phones in the immediate vicinity of electronic
components
External influence/damage
X-ray, ionizing radiation and cosmic radiation
2. Unusually high temperatures - including open flames - as well as the emission of light,
noise, particles, gases, etc. can occur inside and outside the components under fault
conditions caused by, for example:
Component malfunctions
Software errors
Operation and/or environmental conditions outside the specification
External influence/damage
3. Hazardous shock voltages caused by, for example:
Component malfunctions
Influence of electrostatic charging
Induction of voltages in moving motors
Operation and/or environmental conditions outside the specification
Condensation/conductive pollution
External influence/damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a
risk to people with a pacemaker, implants or metal replacement joints, etc. if they are too
close.
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly
6. Influence of network-connected communication systems, e.g. ripple-control transmitters
or data communication via the network
For more information about the residual risks of the drive system components, see the
relevant sections in the technical user documentation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120P PM330 and is the answer not in the manual?

Siemens SINAMICS G120P PM330 Specifications

General IconGeneral
Protection ClassIP20
Input Voltage3AC 380-480V
Input Frequency47 ... 63 Hz
Control Methodvector control
Ambient Temperature Range-10°C to +50°C
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU, USS