Appendix
A.2 Electromagnetic compatibility
Power Module PM330
90 Hardware Installation Manual, 10/2016, A5E32844552B AD
Categories
Category C1
Power Drive System (PDS) of rated voltage less than 1000 V intended for use in the First
(Domestic) Environment.
Category C2
Power Drive System (PDS) of rated voltage less than 1000 V, which is neither a plug-in
device nor a movable device, and when used in the First Environment, is only intended to be
installed and commissioned by a professional.
Note
An expert is a person or organization with the necessary experience for installing and/or
commissioning drive systems (Power Drive Systems
- PDS), including the associated EMC
aspects.
Category C3
Power Drive System (PDS) of rated voltage less than 1000 V intended for use in the second
(industrial) environment and not intended for use within the first (residential) environment.
A.2.2
Compliance with EMC Environment and Categories
EMC interference emission
Note
To comply with the requirements of EN 61800
-3:2004, all drives must be installed in
accordance with the manufacturer's instructions and EMC directives. See also:
EMC
compliant connection
(Page 49).
Cable-conducted (interference voltage) and interference emissions
Category C1
First environment
The Power Modules are not intended for use in Category C1, the first environment. In
order to be able to use Power Modules in Category C1 first environment the following
additional measures must be applied (e.g. filter).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120P PM330 and is the answer not in the manual?

Siemens SINAMICS G120P PM330 Specifications

General IconGeneral
Protection ClassIP20
Input Voltage3AC 380-480V
Input Frequency47 ... 63 Hz
Control Methodvector control
Ambient Temperature Range-10°C to +50°C
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU, USS