User Manual of A90 Series Inverter
24
2.3 Installation Site Requirements and Management
1.
When carrying the inverter, hold its bottom.
If you hold the panel only, the body main fall to hit your feet.
2.
Install the inverter on non-flammable boards (e.g. metal).
If the inverter is installed on a flammable object, a fire may occur.
3.
When two or more inverters are installed in one control cabinet, please install a
cooling fan and keep the air temperature below 50℃ at the air inlet.
Overheating may cause fire and other accidents.
2.3.1
Installation site
The installation site should meet the following conditions:
1.
The room is well ventilated.
2.
The ambient temperature is -10°C to 50°C.
3.
The controller should be free from high temperature and humidity (less than
90%RH) or rainwater and other liquid droplets.
4.
Please install the inverter on a fire-retardant object (e.g. metal). Never install it
on flammable objects (e.g. wood).