-41-
No.EX##-OMN0036
•EX600-DY E /EX600-DY F
Display Content
OFF
The power supply for control and input is OFF.
Green LED is ON
The product is operating normally.
Red LED is ON
The output device has a short circuit.
(Each of output 0 to 15)
Red LED is flashing
Either of the following conditions:
•The output device ON/OFF count has exceeded the set value.
(Each of output 0 to 15)
•The output device is open circuit.
(Each of output 0 to 15)
“0 to 15” LEDs are OFF
The output device is OFF.
(Each LED display number corresponds to output 0 to 15.)
“0 to 15” green LEDs are ON
The output device is ON.
(Each LED display number corresponds to output 0 to 15.)
: Refer to troubleshooting (SI unit Operation Manual of protocol used) for the further details of countermeasures.