Page #46 background image
13 Specification for Option V
13 - 2
13-2 Specifications
The timer is set to have ON time of 0.5sec and OFF time of 0.5min. at the time of shipment from the
factory. Do not change this timer setting. If it is changed, water could be discharged from the outlet
line of the dryer. Service parts number will change depending on the power supply voltage of the
dryer.
13-3 How to perform maintenance
The product needs to be maintained. Clean it in the following procedure periodically.
1) Close the ball valve.
2) Press the test switch and make the residual pressure is released.
3) Remove the strainer and clean it.
4) Reassemble the strainer and open the ball valve.
Power supply voltage of dryer
AC230V
Order number (service parts)
IDF-S0198
Max. operating pressure
1.6MPa
Fluid
Drain
Power supply voltage of drain timer
AC230V±10% (50Hz)
ON time
0.5sec
OFF time
0.5min
ON OFF
ON:SEC OFF:MIN
0.5
2
4
6
8
10
0.5
1
2
3
4
5
Built-in strainer
Ball valve
Test switch
Strainer lid