Pressure Setting
Measurement mode
The measurement mode is the condition where the pressure is detected and displayed, and the switch
function is operating.
This is the basic mode, and other modes should be selected for setting changes and other function settings.
Setting the ON and OFF points of the Pressure switch.
Operation (Hysteresis mode)
When the pressure exceeds a set point, the Pressure switch will be turned ON.
When the pressure falls below the set point by the amount of hysteresis or more, the Pressure switch will be
turned OFF.
The default setting of the Pressure switch is adjusted to be turned on at the central value between
atmospheric pressure and the upper limit of rated pressure range, and turned off when the pressure
decreases by 5% of the span between atmospheric pressure and the upper limit of rated pressure range.
(to change this setting, refer to page 20).
If this condition, shown below, is acceptable, then keep these settings.