-24-
No.PS※※-OMM0003-J
[F 1] Setting of OUT1
Set output method of OUT1.
The output turns on when the pressure exceeds the set value. The default setting of the output set value is
the central value between the atmospheric pressure and the upper limit of the rated pressure range.
The display colour depends on the condition of OUT1.
The default setting of the display colour is as follows: green display when the output is ON and red display
when the output is OFF.
For the operation of each setting, refer to "List of output modes" on page 26.
<Operation>
Press the
or button in function selection mode to display [F 1].
Press the
button.
Move on to setting output mode.
Press the button to set.
Move on to setting of reversed output.
Press the
button to set.
Move on to setting of pressure.
Pressure Setting
Set the pressure based on the setting procedure on page 19.
"P" becomes "n" when reversed output is selected. ([P_1] [n_1])
Hysteresis mode: [P_1]
Window comparator mode: [P1L] [P1H]
Press the
button to set.
Move on to setting of hysteresis.
Select output mode
Press the or button to select output mode.
Select reversed output
Press the or button to select reversed output.