Settingofmin.pressure,max.pressureandswitchoutput
[current/voltageinputtypeonly]
No Keyoperation LEDDisplay
①
Unlockkeys(refertoP8)
②
PressS-key
③
Settheminimumpressurebyusingthe△
and▽keys.
⇔
(displayedalternately)
*Adjustingrange:Refertonote1to6
④
PressS-key
⑤
Setthemaximumpressurebyusingthe△
and▽keys.
⇔
(displayedalternately)
*Adjustingrange:Refertonote1to6
⑥
Gotono.⑪formonitoroutput:analogueoutput(voltageandcurrent)type.
⑦
PressS-key
⑧
SettheP1byusingthe△and▽keys.
⇔
(displayedalternately)
⑨
PressS-key
⑩
SettheP2byusingthe△and▽keys.
⇔
(displayedalternately)
⑪
PressS-key Returnto(current)pressuredisplay.
⑫
Lockkeys(refertoP8)
Minimumpressure(F1)adjustingrange Maximumpressure(F2)adjustingrange
0%
90%
100%
4
0
0
0
12
10
2.5
5
20mA
20mA
5V
10V
-20%
0%
10%
120%
4
0
0
0
12
10
2.5
5
20mA
20mA
5V
10V
100%
(Note1):F1isadjustableinarangefrom-20%to90%oftheratedvalue.
(DEFAULTVALUE:0%)
(Note2):Thepressureoflessthan0%isnotoutput,evenifF1isadjusted
tolessthan0%.
(Note3):F2isadjustableinarangefrom10to120%oftheratedvalue.
(DEFAULTVALUE:100%)
(Note4):Donotinputthesignalaslikeoutputthepressureofmorethan100%.
Pleaseuseinarangeofrating.
(Note5):ThedifferencebetweenF1andF2isadjustableinarangeof10%of
theratedvalue.
(Note6):TheadjustmentlikemakingtherelationofF1>F2isnotavailable.