Wiringmethod
△
! CAUTION
①Proceedcarefully,asincorrectwiringcancausedamage.
②UseDCpowersupplywithsufficientcapacityandalowripple.
③Turnoffthepowersupplytoremoveandinserttheconnector.
④Neverturntherightangledtypeconnectorasitisnotdesignedtoturn.
―5―
Note)Thewirecoloris
forwhenoptional
cableisused.
1 Brown Powersupply
2 White Inputsignal
3 Blue GND(COMMON)
4 Black Monitoroutput
Wiringdiagram(Powersupplyandinputsignal)
Current/Voltagetype(ITV※0※※-0、ITV※0※※-1、ITV※0※※-2、ITV※0※※-3)
Powersupply24VDC (ITV※0※0-※)
12〜15VDC (ITV※0※1-※)
Inputsignal4〜20mADC (ITV※0※※-0)
0〜20mADC (ITV※0※※-1)
0〜5VDC (ITV※0※※-2)
0〜10VDC (ITV※0※※-3)
Powersupply
Input
si gnal
1:
Brown
3:
Blue
2:
White
4:
Black
○
+
○
-
○
+
○
-
Presetinputtype(ITV※0※※-4)
Powersupply24VDC (ITV※0※0-4)
12〜15VDC (ITV※0※1-4)
Fig.1 Relationbetweenpresetpressureandswitch
Presetpressure P1 P2 P3 P4
S1 OFF ON OFF ON
S2 OFF OFF ON ON
Powersupply
1:Brown
3:Blue
2:White
4:Black
○
+
○
-
S1
S2