EasyManuals Logo
Home>SMC Networks>Switch>ZSE80(F)

SMC Networks ZSE80(F) User Manual

SMC Networks ZSE80(F)
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
-23-
PS##-OMM0003-A
Setting of Function
Function selection mode
In measurement mode, press the button for 2 seconds or longer to display [F 0].
Select the display of function setting to be changed, [F ].
Press the
button for 2 seconds or longer in function selection mode to return to measurement mode.
: Some functions are not available depending on part number. All functions are displayed with [F ] and followed with function
description. If a function is not available for specified type, the function is displayed as [- - -].
Default setting
At the time of shipment, the following settings are provided.
If the setting is acceptable, keep it for use.
To change setting, enter function selection mode.
[F 0] Unit conversion function
See page 25
Symbol Pressure range Default setting
ISE80(H) MPa
Nil or M
ZSE80(F) kPa
ISE80(H)
P
ZSE80(F)
psi
[F 1] Parameter setting of OUT1
See page 26
Item Explanation Default setting
Output mode Selects hysteresis mode or window comparator mode. Hysteresis mode
Reversed output Selects reversed output. Normal output
Pressure setting Sets ON or OFF point of the switch output.
ISE80: 0.500 MPa
ZSE80: -50.5 kPa
ZSE80F: 50.0 kPa
ISE80H: 1.000 MPa
Hysteresis Chattering can be prevented by setting hysteresis.
ISE80: 0.500 MPa
ZSE80: -50.5 kPa
ZSE80F: 50.0 kPa
ISE80H: 1.000 MPa
Display colour Selects the display colour.
ON: Green
OFF: Red

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks ZSE80(F) and is the answer not in the manual?

SMC Networks ZSE80(F) Specifications

General IconGeneral
BrandSMC Networks
ModelZSE80(F)
CategorySwitch
LanguageEnglish

Related product manuals