How to start and terminate your work
Keep the ON/OFF key of the UPS unit depressed until
the unit switches on (see enclosed User's guide of the
UPS unit).
Close the cover again.
After having carried out the checks mentioned in para-
graph “How to ensure safety” (F 1-3) insert the appro-
priate key into the key switch on the keyboard of the
HI-SCAN X-ray unit and turn it to the right to position II
as you do when starting a vehicle. As soon as you hear
the X-ray unit switching on, release the key to position
I.
Switch on the monitors if they have not been switched
on together with the unit.
On the keyboard of the HI-SCAN X-ray unit the power-
on indicator
K and, after a short delay, the wait indic-
ator
L light up. The HI-SCAN X-ray unit is carrying
out a self-test first.
After a short moment, the display illustrated appears. In the upper screen area, a test image appears, in
the lower screen area, the indication field (F 1-23) is displayed. In dual view units a second test image
appears on the second screen with a second indication field (F 1-27).
95587412 01/01/09 © Smiths Heimann
I
The UPS unit can be switched off in the same
way if the X-ray unit has to be disconnected
from the mains for a longer period of time.
1-32
I
In units equipped with power fail buffer*
you have to wait about 3 seconds after
the end of a power failure before you can
switch on again.
If you have just turned off the unit also
wait at least 3 seconds before turning on
again.
I
In case of emergency, you can always
switch off conveyors and X-ray generat-
ors of the X-ray unit or the complete unit
by actuating one of the emergency stop
buttons (for the restart see next para-
graph).