To change from 115V to 230V
11. The motor of this pump is dual voltage and
can run on either 115V or 230V. In general,
230V is more economical to run, and
requires a smaller wire size. Most models
are pre-set in the factory to run at 115V.
NOTE: See pump label to verify voltage
prewired at the factory. (Fig. 11)
12. For 230V service, change the following
wires on the terminal board:
a. Using a pair of needle nose pliers,
pull the gray wire with the female ag
connector from the “A” terminal spade
post. Place it to the right on the “B”
terminal space post. (Fig. 12a)
b. Pull the red wire with the female ag
connector from the “L2” terminal. Place it
to the left on the “B” terminal space post.
(Fig. 12b)
A B
L1
L2
G R AY
RED
12a
A B
L1
L2
230V
G R AY
RED
12b
c. Reinstall the rear motor cover. (Fig.12c)
NOTE: To change voltage from 230V to 115V,
simply reverse instructions above.
12c
PUMP ELECTRICAL CONNECTIONS (CONTINUED)
PUMP PRIMING & STARTUP
PRIMING
CAUTION: All pumps must be primed
(lling the cavity with water) before they are
rst operated. This may take several gallons
of water, as the suction line will be lled in
addition to the pump cavity.
1. Remove the priming plug with pressure
gauge and air relief plug.
(Fig. 1a with built-in ejector)
(Fig. 1b with bolt-on ejector)
2
IL1352
Water Level in
Pump Cavity
3
3. Replace air relief plug and continue adding
water to pump cavity until water reaches the
top of the priming plug. (Fig. 3)
2. Slowly ll pump cavity until water comes out
of air relief hole on top of the pump. (Fig. 2)
IL0068
Air relief plug
Motor: 98L105
HP: 1/2 PH 1 Hz 60
Volts 115/230 S.F. 1.2 Amps 6.4/3.2
S.F. Amps: 8.6/4.3 RPM 3450 Type C
Duty: Cont. Temp 65C KVA Code G
Frame 56L Ins Class B
Factory prewired for 115V Thermally protected automatic
Check voltage of power source Use copper conductors only
ELECTRICAL HAZARD
Improper installation may result in  re, explosion, electrical short or injury. Replace all covers
before operating. Ground motor in accordance with local and national electrical codes.
Disconnect power source before touching internal parts. Motors equipped with automatic
protection may restart without warning.
See instruction manual for proper installation procedure.
Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.
Consulte el instructive para conocer el procedimiento de instalación correcto.