STIHL 064, 066 63
8.3 Switch Shaft
Top:
Top: Removing switch shaft
Removing short circuit wire
Bottom:
Bottom: 1 = Throttle rod
Prying out switch shaft retainer 2 = Contact spring Fitting retainer
Place the retainer in position and press it
down into the seat and over the switch
shaft.
- Remove the throttle trigger/inter- - Take the switch shaft out of its
lock lever - see 8.2. pivot mounts.
- Pull the contact sleeve of the Installation of the switch shaft is a
short circuit wire out of the switch reversal of the removal sequence.
shaft.
Note: The Master Control lever
- Move the Master Control lever to must be in the "RUN" position
the "RUN" position. when you install the switch shaft -
the throttle rod must be above the
- Use a screwdriver to pry retainer switch shaft and the contact spring
and switch shaft out of right-hand must locate on the cam for the
seat. short circuit wire.