8-6
PROCEDURE DURING STORAGE
Once a month, recharge the battery with a
specified charging rate (Ampere). Standard
charging rate is 0.5A × 5 to 10 hours.
PROCEDURE FOR RETURNING TO
SERVICE
• Clean the entire motorcycle.
• Reinstall the battery.
NOTE: Make sure that the battery vent hose
is routed properly. Be sure to connect the
positive terminal first, then connect the neg-
ative terminal.
• Remove the spark plug. Turn the engine
a few times by putting the transmission
in top gear and turning the rear wheel.
Reinstall the spark plug.
• Drain the engine oil thoroughly. Replace
the oil filter with a new one and pour
fresh oil as outlined in this manual.
• Adjust the pressure of tyres as described
in the TYRE section.
• Lubricate all places as instructed in this
manual.
• Do the “INSPECTION BEFORE
RIDING” as listed in this manual.