6
| Installation
Fans 166 W 338 W
Total power consumption
1836 W 2008 W
Fuse 10 A 13 A
6 Installation
This section describes how to install the unit correctly. To ensure a proper and fail-free operation, it is important that
the unit is installed according to these instructions.
6.1 Unpacking
Verify that all ordered equipment are delivered before starting the installation. Any discrepancies from the ordered
equipment must be reported to the supplier of Systemair products.
6.2 Where/how to install
The SAVE VSR 300/500 should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.), but
can also be installed in the loft space.
When choosing the installation position, consideration must be taken that the unit requires regular maintenance. Floor-
ing boards must be mounted up to and under the unit. Light and mains supply should be installed. Leave free space for
removing of inspection doors and for taking out main components inside the unit.
The SAVE VSR 300/500 are supplied with approximately 1 m cable and plug for 230V, single phase earthed connection.
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waist water drain-
age and other pollution sources like exhaust from traffic etc. Stale discharge air should ideally be led via a roof unit to
the outside and with a good distance to any outdoor air intake, windows etc.
Note:
If the passage to the installation location is narrow, remove the side covers and the side cover support
brackets.
6.3 Installation procedure
A. Upright installation on the floor. Left and right connections are possible.
The enclosed self adhesive vibration dampers must be used.
B. Ceiling installation. Left and right connections are possible.
A ceiling mounting kit is required. Not delivered with the unit. Needs to be ordered separately.