16
| SAVECair control
Icon Text
Description
Defrosting
Function prevents formation of the ice on the heat exchanger during cold
outdoor temperatures.
Secondary air
Warm air from the living space is used to defrost the heat exchanger using a
damper inside the outdoor air duct. The unit switches from outdoor air to
secondary air while the extract air fan stops and warm secondary air increases
the temperature inside the heat exchanger.
Vacuum
cleaner
Function sets speed of supply air fan to High level and extract air fan to Low
level to increase air pressure within the apartment for better dust collection
through central vacuum cleaner.
Function can be activated via digital input — Central Vacuum Cleaner
Function.
Always active while digital input is activated.
Cooker hood
Sets speed of supply air fan to High level and extract air fan to Low level to
increase air pressure within the apartment for better airborne grease and steam
collection in the kitchen.
If a cooker hood with integrated fan is used, then it is recommended to set
airflow levels of both fans to Normal.
Function can be activated via digital input — Cooker Hood Function.
Always active while digital input is activated.
User lock
Function indicates that the system is locked with a password and cannot be
edited or settings changed in any way. System must be unlocked first to make
changes.
8.7 Main menu
User settings and advanced settings
8.7.1 Unit Information
A basic read-only information about status of the unit, configured components and inputs/outputs.
211458 | A002