Accessories
|
43
3. Configure the contactor switch that controls the dampers. Go to Output menu. Select DIGITAL tab. Select the digital
output to which the contactor is connected. Example if it is connected to DO3 on the connection board, then select
DIGITAL OUTPUT 3 and select signal type as Outdoor-/Exhaust Air Damper from the output type list.
10.6 Filters
The filters need to be replaced when polluted. New sets of filters, if possible, should be acquired directly from Systemair
to meet filter quality standards. If that is not possible, please contact your installer or wholesaler.
The filter type is labelled on the top of the filter
Component/product Article number:
VSR 300:
BFVSR 300 G3 Supply air 208103
BFVSR 300 G3 Extract Air 208105
BFVSR 500 F7 Supply air 208107
VSR 500:
BFVSR 500 G3 Supply air 208106
BFVSR 500 G3 Extract Air 208108
BFVSR 500 F7 Supply air 208107
10.7 Passive House function
To enable Passive House function:
1. Activate Passive House function in menu (HMI or APP). Go to Service menu. Enter your password (default 1111).
Then go to Components menu, select Heat Exchanger and turn on Passive house function.
2. Install filter kit approved by Passive House Institute (PHI).
Component/product Article number:
Filter kit BFVSR 300 211585
Filter kit BFVSR 500 211586
211458 | A002

Other manuals for SystemAir SAVE VSR 500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SystemAir SAVE VSR 500 and is the answer not in the manual?

SystemAir SAVE VSR 500 Specifications

General IconGeneral
BrandSystemAir
ModelSAVE VSR 500
CategoryFan
LanguageEnglish

Related product manuals