Technical Manual
31. May 2007 Revision: V1.10 5-2
Copyright © 2007, JohnsonDiversey, Inc.
07.0 swingo 450B - software u parameters.fm - 31. May 2007
5 Software & Parameter
5.1 Configuration Software
5.1.1 How to readout data
The software is needed to read out data or to change/adjust certain parameters
(It runs on electronics V2.0 or higher, default values on CD are according V2.4)
5.1.2 Requirements
• TASKI swingo (series models)
• Notebook
• Adapter cable set 4122673 (17606-39): Software, Cable
5.1.3 Step by step
• Switch off machine / unplug the mains driven machines
• Remove the electrical cover
• Connect the PC with the machine
• Assemble the electrical cover again, but do not fix it in such a
way, that you squash the PC connection cable
If you do not assemble the cover, it is not possible to switch on the
machine
• Switch on computer
• Switch on the machine / plug in the mains driven machines
• Start software
• Double click on „Parameter list“(as you do not have the
password, you can only change some parameters)
• Change/adjust parameters according to parameter list (a red
cross in the title shows: no access for any parameters in the
file, these parameters are marked grey)
• when all necessary changes/adjustments have been done
done, store the data on the board with icon „Programming
Board“
• Log off the program with „Close“
• Switch off machine / unplug the mains driven machines
• Disconnect Machine and computer
• Remount electronic cable
• Test all functions of the machine