TO THE INSTALLER
1-3
Model C723
To the Installer
1
authorized Taylor service technician.
• The main power supplies to the machine must
be disconnected prior to performing installation,
repairs, or maintenance.
• For Cord-Connected Machines: Only Taylor
service technicians or licensed electricians may
install a plug or replacement cord on the
machine.
• Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to
local codes.
• Stationary machines that are not equipped with
a power cord and a plug or another device to
disconnect the appliance from the power source
must have an all-pole disconnecting device with
a contact gap of at least 0.125 in. (3 mm) in the
external installation.
• Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
• If the supply cord is damaged, it must be
replaced by the manufacturer, service agent, or
a similarly qualified person to avoid a hazard.
• Secure supply cord ground lead to machine in a
location where if the cord is pulled the main
power leads become taut before the ground
lead can break loose.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
distributor for service.
Beater Rotation
NOTICE! Beater rotation must be
counterclockwise as viewed looking into the freezing
cylinder.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at the
freezer main terminal block only. To correct rotation on a
single-phase machine, exchange leads inside the beater
motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box, located behind
the service panel.
It is recommended that beater rotation adjustment be
performed by a Taylor service technician.
Optional Carts
There are 2 optional carts available.
1. C20600-AFB: ADA-compliant height cart, not
equipped with a door.
2. C20600-000: Standard height cart with reversible
front door panel and rear panel.
Note: If the door is required on the rear of the cart
instead of the front, the front door panel and the rear
panel can be reversed. To reverse these panels,
remove the five screws on each panel. Reverse and
reinstall the panels, making sure all screws are
reinstalled.
IMPORTANT! For safety purposes, the
freezer must be bolted to the cart using all four bolts.
Failure to comply could result in personnel injury and
equipment damage.