EasyManuals Logo
Home>TCL>Controller>uTC52

TCL uTC52 User Manual

TCL uTC52
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
39
17. Applications
17.1 RAMP & SOAK
z RAMP
I. SET2.1=1ÎTo display AL3
II. SET4.1=1ÎTo display ALD3
III. ALD3=9ÎOpen RAMP option
IV. Then, AL3 will not display. It was replaced by RAMP.
RAMP
0 0.0 0
Range00.00 ~ 99.99(/ min)
(If RAMP is not usedplease set
ALD3 to 0)
z SOAK
I. ALD1 / ALD2=19
Î To use Sock Timer.
II. AL1 / AL2 will display as below:
AL1
0 0 . 0 0
Range00.00 ~ 99.59(Hour.Minute)
z Example
SV=100RAMP=10.00 ( /min) AL1=00.10 minPV=25
100
PV=25℃
5 seccons(Start RAMP function)
Time on
if PV > = SV(100℃)
Time up
AL1 on
SV=PV (When start RAMP function)
SV=SV+RAMP
AL1
00.10
00.01
00.10
Sock Timer
counts
1sec.
Power on