EasyManuals Logo
Home>TECO>Servo Drives>JSDEP Series

TECO JSDEP Series Simplified Manual

TECO JSDEP Series
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
28
Chapter 4 Parameter
4-1 Explanation of Parameter groups
There are 10 groups of parameters as listed below.
4-2 Parameter Display Table
Diagnosis Parameter
Communication
Address
Parameter Name & Function
RS232 RS485
dn-01 Selected control mode N/A N/A
dn-02 Output terminal signal status. 6AFH N/A
dn-03 Input terminal signal status. 6CBH N/A
dn-04 Software version C42H N/A
dn-05 JOG mode operation N/A N/A
dn-06 Reserved C43H N/A
dn-07
Auto offset adjustment of external analog
command voltage.
5FCH N/A
dn-08 Servo model code. 50CH N/A
dn-09 ASIC software version display 98CH N/A
Alarm
Code
Description
Un-xx
Status Display Parameters.
dn-xx
Diagnostics Parameters.
AL-xx
Alarm Parameters
Cn-0xx
System Parameters
Tn1xx
Torque Control Parameters
Sn2xx
Speed Control Parameters
Pn3xx
Position Control Parameters
Pn4xx
Internal Position Control
Parameter
qn5xx
Quick Set-up Parameters
Hn6xx
Multi-function I/O parameters
Control Mode Code
Signal
Control Mode
ALL
All Control Mode
Pi
Position Control Mode(Internal Positional Command )
Pe
Position Control Mode(External Puls Command)
Pt
Tool Turret Control Mode
S
Speed Control Mode
T
Torque Control Mode
Definition of Symbols
Symbol
Explanation
Parameter becomes effective after recycling the power.
Parameter is Effective without pressing the Enter key.
Parameter is not effected by Cn029.

Table of Contents

Other manuals for TECO JSDEP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TECO JSDEP Series and is the answer not in the manual?

TECO JSDEP Series Specifications

General IconGeneral
BrandTECO
ModelJSDEP Series
CategoryServo Drives
LanguageEnglish