Appendix
C
Table C-1
Confidence Test Numbers and Affected Functions
Test Number
01
02
03
04
05
06
GP 11
DM 76
CT
81
- 87
Description
Controller Timing Signal Missing or Wrong Period
Momentary Switch Stuck
Readout Interface or Memory Failure
Calibration Data Parity or Checksum Error
Main Board Failure Detected by Auto Level Trigger on LINE
Source
Memory-Battery Voltage Too High or Too Low
GPIB Interface Failure Detected
Digital Multimeter Failure Detected
Counter-Timer-Trigger Failure Detected