Commands Listed in Alphabetical Order
Syntax
TRIGger:A:LOG
Ic:INPut:CLOCk:EDGE {FALL|RISe|EITher}
TRIGger:A:LOGIc:INPut:CLOC k:EDGE?
Arguments
RISe species to trigger on the rising or positive edge of a signal.
FALL species to trigger on the falling or negative edge of a signal.
EITher species to trigger either on the falling or rising edge of a signal.
TRIGger:A:LOGIc:INPut:CLOCk:SOUrce
Sets or returns the channel to use as the clock source. The clock can be selected as
NONE. A selection of None implies pattern trigger. Any other selection implies
state trigger.
Group
Trigger
Syntax
TRIGger:A:LOGIc:INPut:CLOC k:SOUrce {CH1|CH2|CH3|CH4 |
D0|D1|D2|D3|D4|D5|D6|D7|D8 |D9|D10|D11|D12|D13|D14|D15|NONE}
TRIGger:A:LOGIc:INPut:CLOC k:SOUrce?
Arguments
CH1–CH4 species the analog input channel source.
D0–D15 species the digital input c hannel source.
NONE species a Pattern trigger.
TRIGger:A:LOGIc:INPut:D<x>
Sets or returns the logic pattern for a trigger on digital channel <x>, where x
is t
he channel number.
Group
Trigger
Syntax
TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X }
TRIGger:A:LOGIc:INPut:D<x> ?
Arguments
High species the logic high state.
Low species the logic low state.
X species a "don't car e" sta te.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-321

Other manuals for Tektronix DPO2012

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012 and is the answer not in the manual?

Tektronix DPO2012 Specifications

General IconGeneral
BrandTektronix
ModelDPO2012
CategoryTest Equipment
LanguageEnglish

Related product manuals