Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:SETHold:CLOCk:E DGE {FALL|RISe}
TRIGger:A:SETHold:CLOCk:E DGE?
Arguments
FALL specifies polarity as the clock falling edge.
RISe specifi es polarity as the clock rising edge.
Examples
TRIGGER:A:SETHOLD:CLOCK:E DGE RISE specifies the polarity as the clock
rising edge.
TRIGGER:A:SETHOLD:CLOCK:E DGE? might return :TRIGGER:A:SETHOLD:
CLOCK:EDGE RISE
indicating that polarity is specified as the clock rising edge.
TRIGger:A:SETHold:CLOCk:SOUrce
Sets or returns the clock source for the setup and hold triggering.
Group
Trigger
Syntax
TRIGger:A:SETHold:CLOCk:S OUrce {CH1|CH2|CH3|CH4|
D0|D1|D2|D3|D4|D5|D6|D7|D 8|D9|D10|D11|D12|D13|D14|D15}
TRIGger:A:SETHold:CLOCk:S OUrce?
Related Commands
TRIGger:A:SETHold:DATa:SOUrce
Arguments
CH1–CH4 specifies the input channel number.
D0-D15 specifies the input digital channel number.
Examples
TRIGGER:A:SETHOLD:CLOCK:S OURCE CH1 specifies channel 1 as the clock
input for setup and hold input.
TRIGGER:A:SETHOLD:CLOCK:S OURCE? might return :TRIGGER:A:S ETHOLD:
CLOCK:SOURCE CH4
indicating that channel 4 is the clock source for the setup
and hold trigger input.
TRIGger:A:SETHold:CLOCk:THReshold
Sets or returns the clock voltage threshold for the s etup and hold trigger.
2-334 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual